Exoweight Notes

Optics and photonicsAlgorithm, Construction Level 1 · Supporting resultRigorously checked, not machine-checked

Under one linearly tracked laser over a temperature span, the minimum number of ring filters needing a permanent thermal-slope trim equals the number of sites minus the largest number of untrimmed slope-tolerance intervals sharing a feasible common tracking slope (an O(n log n) endpoint sweep), and in the 16-lane worked example with bounded center trim the single required trim works exactly for doses 1.4-2.2 pm/K with collateral midpoint shift |p| <= 20u - 8 pm

Level 1 of 5 · Supporting result

Could support a paper, cannot carry one.

Why this level
A general but elementary interval-stabbing rule for slope-trim site count under common laser tracking, now with an LP-checked dose and collateral window for one illustrative 16-lane example under bounded center trim. It has no measured trim response or device test, so it can support a site-selection and trim-spec section of a WDM athermal-trimming paper but cannot carry one.
Verification
Rigorously checked, not machine-checkedinternal; not externally peer-reviewed

Summary

Model: one thermal domain of span ΔT, rings with fixed measured slopes s_i and detuning budgets ±e_i, static center trim, and one laser shared by all lanes. Each ring's tolerance interval is U_i = [s_i − 2e_i/ΔT, s_i + 2e_i/ΔT], and its reachable set V_i adds the attainable slope changes. F is the intersection of all V_i with the tracking slopes allowed by the laser and by immutable TX filters. If F is empty the link is infeasible. Otherwise the minimum number of slope-trimmed sites is n minus the maximum, over g in F, of the number of U_i containing g. Necessity follows from endpoint displacement, and sufficiency from linear tracking at slope g with midspan centering. For interval strokes the optimum is found by an endpoint sweep. In the 16-lane example (slopes −8.4/−9.0/−9.6 ×5 plus an outlier at −11.8 pm/K, TX at −9.2 pm/K, ±20 pm, ±20 K) exactly one trim is needed. A second finding treats this example with only ±10 pm of remaining RX center trim and a collateral midpoint shift p from the trim. A direct LP over laser midpoint/slope, RX centers and dose finds that without a trim the best worst error is 34 pm and that trimming any other site cannot help. A trim of slope u on the outlier works exactly for 1.4 ≤ u ≤ 2.2 pm/K (2.2 is the assumed stroke limit) with |p| ≤ 20u − 8 pm. At full dose the collateral limits are 36 pm (free laser midpoint), 26 pm (midpoint pinned), 32 pm (2 pm reserved on every site) and 16 pm (no center trim), and in general C + 16 + min(C,16) pm for center stroke ±C. Each limit is attained and is exceeded under 0.01 perturbations. Evidence: exact checks against a brute-force subset search on 216 three-site inventories, and floating-point LP checks at sampled doses and center strokes. Limits: one thermal domain; linear slopes. The general bounded-center, multi-domain and multi-process-case extensions are argued but checked only on this example, and disconnected strokes are not tested. The dose-window and C formulas are verified at sample points, not proved, and no run output is retained. Joint center/slope response of real trims (for example, photobleaching) has not been measured, and there is no device test. The reduction is elementary interval stabbing, and the example limits follow from a small LP.

Notes are written for active Results at level 2 or higher. This page shows the record as the assessor wrote it.

Findings

Finding 1AlgorithmHeadlineRigorously checked, not machine-checkedinternal; not externally peer-reviewed
Minimum number of filters needing a permanent thermal-slope trim (in addition to center trim) under a common linearly tracked laser over span DeltaT: with U_i = [s_i - 2e_i/DeltaT, s_i + 2e_i/DeltaT] and trimmed sets V_i, intersect V_i with laser and immutable-site constraints to get F; the minimum is (#candidate sites) minus the maximum number of U_i containing a common g in F (empty F = infeasible). Necessity by endpoint displacement, sufficiency by linear tracking with midpoint centering; disconnected strokes require sweeping all component endpoints. Worked 16-lane example (slopes -8.4/-9.0/-9.6 x5, outlier -11.8, TX -9.2 pm/K, +-20 pm, 40 K): exactly one trim needed.
Finding 2ConstructionHeadlineRigorously checked, not machine-checkedinternal; not externally peer-reviewed
For the illustrative 16-filter bank of optical-dwdm-design (five each at -8.4/-9.0/-9.6 pm/K, outlier -11.8, immutable TX -9.2 pm/K, H = 20 K half-span, E = 20 pm tolerance, +-C = 10 pm remaining RX center trim, rigid tracking laser), a permanent slope trim u on the outlier with collateral midpoint shift p works iff 1.4 <= u <= 2.2 pm/K and |p| <= 20u - 8 pm; at full +2.2 pm/K dose the sharp collateral limits are 36 pm (free laser midpoint), 26 pm (midpoint pinned), 32 pm (2 pm reserved on every site), 16 pm (no remaining center trim), and in general C + 16 + min(C,16) pm. Without the trim the best achievable worst error is 34 pm.

Provenance

Evidence files as they stood at assessment commit 84715bc.

Finding 1 f1

Finding 2 f2

Assessment history

DateLevelCommitRationale
2026-11-261 · Supporting result84715bcA general but elementary interval-stabbing rule for slope-trim site count under common laser tracking, now with an LP-checked dose and collateral window for one illustrative 16-lane example under bounded center trim. It has no measured trim response or device test, so it can support a site-selection and trim-spec section of a WDM athermal-trimming paper but cannot carry one. claude-opus-5-5
2026-11-261 · Supporting resultfde6dcaA general and correct site-count rule for slope trimming under common laser tracking. It reduces by a short endpoint-displacement argument to standard interval stabbing in one linear thermal domain, and has no measured joint trim response or device test. It could support a site-selection section of a WDM athermal-trimming paper but cannot carry one. claude-opus-5-5