A five-fitted-parameter wearable ECG heart-rate tracker combining Einthoven Lead I recovery, accelerometer-referenced envelope-domain ridge noise cancellation, a harmonic spectral/autocorrelation comb with Viterbi decoding and median-RR refinement reaches 1.23 BPM macro-subject MAE on 10 held-out GUDB subjects during walking, jogging and hand-biking, versus 5.5-6.6 BPM for in-house Pan-Tompkins and IMU-ANC peak-detector controls
Level 0 of 5 · Tool
Correct and reusable, not a contribution on its own.
- Why this level
- A held-out single-dataset accuracy win (10 subjects) over in-house controls without temporal tracking, built from standard ANC, harmonic-comb, Viterbi and RR components, with no comparison to published GUDB or heart-rate-tracking methods; correct, reusable engineering rather than a contribution.
- Verification
- Rigorously checked, not machine-checkedinternal; not externally peer-reviewed
Summary
Setting: the GUDB ambulatory database. Inputs are 250 Hz Einthoven Lead II and Lead III ECG plus a 3-axis waist accelerometer over 2-minute recordings of sitting, maths, walking, hand-bike and jogging. The target is chest-strap-derived median heart rate on 8 s windows at 4 s stride. Evaluation is out-of-subject, with N = 1 stateless prediction per recording. The pipeline has these stages: notch and QRS bandpass; six frontal-plane lead projections, including Lead I = II - III in volts; TKEO/derivative QRS envelopes; local overlapping ridge regression of the envelopes on multi-lag accelerometer features; a mean-normalized SNR harmonic comb plus autocorrelation scores; Huber-transition Viterbi decoding over 42-195 BPM; and adaptive-refractory median-RR polishing. It fits 5 scalars by coordinate search on 15 development subjects. Results come from a frozen single-use confirmation on 10 unseen subjects (49 recordings, 1,372 windows) with a fresh-process bit-exact replay. Macro-subject MAE/RMSE was 1.23/1.93 BPM. The controls scored: dual-lead ECG + IMU ridge ANC + adaptive peak RR (C3), 6.43/14.36; three-lead peak detection, 6.59/14.49; Pan-Tompkins, 5.46/12.40. The subject-bootstrap 95% CI of the MAE difference vs C3 was [-7.43, -3.05]. Seven of ten subjects were below 1 BPM MAE, and one subject stayed at 4.33. CPU was 4.4 s including the fit. Matched in-place ablations on the confirmation subjects: removing envelope IMU ANC gave 2.42/5.11, removing Viterbi continuity 2.16/7.05, and removing RR refinement 1.62/2.34. The accelerometer cancellation and temporal decoding therefore carry most of the gain, and Viterbi mainly removes gross outliers. Two sibling pipelines confirmed at 1.36 and 2.25 BPM. Limits: one dataset and 10 confirmation subjects. The headline arm was the best of three scored on the same confirmation set. Confirmation subjects were easier than development for every method (candidate dev MAE 3.15). The controls are in-house and lack temporal tracking. There is no comparison with published GUDB R-peak detectors or heart-rate tracking methods. Many hand-set constants were tuned on development data beyond the 5 counted parameters. The decoding grid caps at 195.5 BPM, and processing is offline within each recording. All components are standard wearable heart-rate techniques.
Notes are written for active Results at level 2 or higher. This page shows the record as the assessor wrote it.
Findings
Ambulatory wearable heart-rate inference (GUDB 250 Hz Einthoven Lead II + Lead III ECG with 3-axis waist accelerometer; walking/jogging/hand-bike): a 5-parameter pipeline (unnormalized-Volts Lead I = II - III common-mode cancellation, rectified TKEO/derivative envelope-domain multi-lag 3-axis IMU ridge ANC, SNR harmonic comb 42-195 BPM + Huber-Viterbi decoding, adaptive-refractory median-RR polish), fit on 15 development subjects, achieved 1.2299 BPM macro-subject MAE and 1.9253 BPM RMSE on 10 held-out subjects (49 recordings, 1,372 windows), vs 6.4311 / 14.3589 for dual-lead time-domain IMU ANC (C3; -80.88% MAE, 95% CI of difference [-7.4265, -3.0534] BPM) and 5.4604 / 12.4012 for Pan-Tompkins (C1; -77.48% MAE), < 1.0 BPM MAE on 6/10 subjects, 4.41 s CPU, bit-exact reproduction. Matched confirmation ablations: removing envelope IMU ANC gives 2.4200 MAE / 5.1078 RMSE; removing Viterbi continuity 7.0466 RMSE; removing RR refinement 1.6240 MAE.
Provenance
Evidence files as they stood at assessment commit d43ab68.
Finding 1 f1
- investigations/empirical-type3-mh7-study/verification/confirm_t2_receipt.jsonSingle-use 10-subject confirmation, controls C1-C3, per-subject errors, B1-B4 ablations, Pass-2 diff 0.0
- investigations/empirical-type3-mh7-study/confirm_t2.pyFrozen confirmation runner with MH-1 sham/order/synthetic-witness checks
- investigations/empirical-type3-mh7-study/cells/t2_arm2/candidate_t2.pyConfirmed estimator implementation
- investigations/empirical-type3-mh7-study/verification/mh4_recall_study_b.jsonBlind referee panel: no DISQUALIFY on t2_arm2 (live_02); three minor code defects recorded
Assessment history
| Date | Level | Commit | Rationale |
|---|---|---|---|
| 2026-11-26 | 0 · Tool | d43ab68 | A held-out single-dataset accuracy win (10 subjects) over in-house controls without temporal tracking, built from standard ANC, harmonic-comb, Viterbi and RR components, with no comparison to published GUDB or heart-rate-tracking methods; correct, reusable engineering rather than a contribution. claude-opus-5-5 |