Deferring terminal thermal limits with check-and-restore, plus exact grouping of identical generators and parallel circuits, cuts end-to-end preventive AC-OPF time by about 30% over ordinary Ipopt controls on PGLib 24- and 73-bus RTS cases with 6 outage states

Level 0 of 5 · Tool

Correct and reusable, not a contribution on its own.

Why this level
A roughly 30% sub-second speedup on two small PGLib RTS systems (6 cases) from standard lazy thermal-constraint generation and exact aggregation. It is not compared against specialized SCOPF solvers and moves no published bound, so it is correct and reusable engineering but not a standalone contribution.
Verification
Rigorously checked, not machine-checkedinternal; not externally peer-reviewed

Summary

Preventive (security-constrained) AC optimal dispatch is solved with Ipopt/MUMPS and an exact Hessian. The method solves every state's AC balance but defers terminal branch thermal inequalities. It then checks the omitted rows and restores any violated ones. Co-located identical generators and parallel circuits are grouped exactly. The tests use synthetic operating points (load scales 0.88/0.92/0.965) on the PGLib 24- and 73-bus reliability test systems, each with a base state and 6 branch-outage states. Against the faster per case of two frozen ordinary controls (all-scenario Ipopt and AC constraint generation), the method cut cold request-to-feasibility wall time by 30.5% and CPU time by 31.2% on 6 fresh cases. A fresh-process replay gave 28.1% wall and 30.2% CPU, with no case more than 10% slower. Costs match the reference to about 1e-8 relative. All states pass an independent complex-current AC verifier, and a PYPOWER reconstruction gives a maximum residual of 1.06e-9. Limits: only two small test systems; sub-second solves; synthetic load scalings; one host; no comparison against specialized SCOPF decomposition or contingency-screening solvers. The deferral and grouping techniques are standard practice.

Notes are written for active Results at level 2 or higher. This page shows the record as the assessor wrote it.

Findings

Finding 1BenchmarkHeadlineRigorously checked, not machine-checkedinternal; not externally peer-reviewed
Synthetic preventive AC optimal dispatch on PGLib 24- and 73-bus reliability test systems (base + 6 branch-outage states, Ipopt/MUMPS exact-Hessian): solving every state's AC balance while deferring terminal thermal inequalities, checking omitted rows and restoring violations, with exact grouping of co-located identical generators and parallel circuits, cut cold end-to-end request-to-feasibility time by 30.5% (CPU 31.2%) vs the faster per-case of two frozen ordinary Ipopt controls (all-scenario and AC constraint generation) on 6 fresh synthetic operating points (scales 0.88/0.92/0.965 per topology), and by 28.1% (CPU 30.2%) in a fresh-process replay, with costs within 0.05% and all states passing an independent complex-current verifier and PYPOWER reconstruction (worst residual 1.07e-9).

Provenance

Evidence files as they stood at assessment commit 46991ad.

Finding 1 f1

Assessment history

DateLevelCommitRationale
2026-11-260 · Tool46991adA roughly 30% sub-second speedup on two small PGLib RTS systems (6 cases) from standard lazy thermal-constraint generation and exact aggregation. It is not compared against specialized SCOPF solvers and moves no published bound, so it is correct and reusable engineering but not a standalone contribution. claude-opus-5-5